Order Line:  01142 357717

LA240 Home Hearing Loop Pad System


£131.82 exl VAT

The LA240 Home Hearing Loop Pad System provides a practical solution for hearing aid users to listen more easily to their TV or Audio equipment.  Any hearing aid with the “T” or “Loop” program can access the hearing loop.

  • Optical and Coaxial digital audio input
  • Separate Mains power supply
  • Memory of control settings allowing remote power switching
  • Digital Rotary Volume and Tone controls with LED indication
  • Source selection of all inputs from front panel, mixing of inputs is possible.
  • Loop pad coverage up to 1m2
  • Microphone with 1.2m lead included
  • On/Off Mains Switch
  • 2 Microphone Inputs
  • 3 Line inputs

Please Note: The LA240 Home Hearing Loop Pad System is supplied with a Loop Pad.  If Loop Cable is required, please see the LA240 Home Hearing Loop System (135-250).

In stock

Description

The LA240 Home Hearing Loop Pad System provides a practical solution for hearing aid users to listen more easily to their TV or Audio equipment.  Any hearing aid with the “T” or “Loop” program can access the hearing loop.

With no direct connection between the user and a TV or Audio equipment, the user is able to listen comfortably without distraction.

The Loop system picks up the sound from a TV via a direct connection or microphone. This is fed to the amplifier and then passed to the loop pad using the provided loop cable.  The loop pad in turn transmits the sound inductively to a hearing aid with the loop facility.

The user may then adjust the loop volume or tone to suit their own hearing preference without affecting others.

Please Note: The LA240 Home Hearing Loop Pad System is supplied with a Loop Pad.  If Loop Cable is required, please see the LA240 Home Hearing Loop System (135-250).

The LA240 Loop Pad System creates a smaller localised loop directly where the pad is placed.  Ie. Place the pad under the cushion of the chair you always sit in.  A Loop Pad is an alternative to loop cable and creates a localised or portable system.  Firstly, this means that no installation is required of loop cable around the room.  Secondly, this avoids interference with other systems and can provide confidentiality when required.

This kit comes with the loop pad and 5 meters of loop cable to connect to the pad.

 

Key Features

  • Optical and Coaxial digital audio input
  • Separate Mains power supply allowing use by DC inputs from 12-24V, one version covers all markets
  • Memory of control settings allowing remote power switching
  • Digital Rotary Volume and Tone controls with LED indication
  • Source selection of all inputs from front panel, mixing of inputs is possible.
  • Loop pad coverage up to 1m2
  • Electret Microphone with 1.2m lead included
  • Loop Level Indicator
  • Priority Function Control
  • Automatic Gain Control
  • On/Off Mains Switch
  • Blue LED Function Indicators
  • Red LED Level Indicator
  • 2 Microphone Inputs
  • 3 Line inputs

System Includes

  • LA240 amplifier
  • Power supply & Mains Lead
  • Digital Audio Optical TOSlink
  • 1 Loop Pad
  • 1 Direct Connection lead kit
  • 5 meters loop cable

Technical Specification

Power Supply:

  • 18V 1.5A Power Supply
  • 12-24V DC 2A External Supply

Controls:

  • Rotary Volume Control
  • Rotary Tone control
  • On/Off power switch
  • Source selector switches
  • Priority switch

Input connections:

  • Digital Audio TOSlink/Coaxial
  • 2 x Microphone inputs. 3.5mm mono jack plug. DC powered 5V for electret microphones
  • 2x Aux In Left/Right line inputs. Phono/RCA sockets. For direct connection to a TV sound output or other audio sources via SCART or other suitable sockets.

Output connections:

  • Push grip connectors for loop cable or loop pad (Labelled: Loop Cable). Loop will give full output with loop resistance between 0.5 and 1.5 Ohms.
  • 3.5mm stereo jack for headphones (Phones) 8-60 Ohms

Loop output:

  • 3.0A output current @ 100-5KHz. Meets BS EN60118-4:2006 for a loop not exceeding 6.5m (20ft) in width. Suitable for areas up to 70m2

Loop Cable:

  • Single turn loop cable. The system supplied with 40m (130ft) 24/0.2mm (0.75mm2) single core PVC insulated cable. Min cable length 11m = 0.5 Ohms

Indicators:

  • Red & Blue LED’s

 

Documentation

LA240 Home Hearing Loop System Instructions

FAQ

How close do I need to be to the loop pad?

The loop pad system creates a field of approximately 1m2.  Usually the pad would be positioned under the chair seat cushion or back cushion.  It could be placed on the floor under the chair but obviously the further away the pad is to the person, the weaker the signal gets.

 

Can the control box be connected to a Hi Fi amplifier as well as a TV?

Yes.  It can connect to them both at the same time. You simply select the audio input you wish to listen to on the LA240 unit menu.

The Digital Audio Optical TOSlink cable supplied would be used to connect to the TV.  It is also supplied with a 1.2m Stereo Phono-Phono lead and a 3.5mm jack plug adaptor which would be used for Hi-fi system.

 

Does the pad have to be within 5m of the control box?

Yes – the length of loop cable supplied is 5m.

Reviews

There are no reviews yet.

Be the first to review “LA240 Home Hearing Loop Pad System”

Your email address will not be published. Required fields are marked *